Produktvergleich
UPS 1 [x] | UPS 2 [x] | UPS 3 [x] | |
Allgemeine Merkmale | |||
Model | |||
Main Picture | |||
Pictures | |||
Item Number | 10121105 | 10121105 | 10121105 |
EAN | 4260074981629 | 4260074981629 | 4260074981629 |
Features |
|
|
|
Typ | Line-Interactive | Line-Interactive | Line-Interactive |
Kapazität | 3000VA / 2100W | 3000VA / 2100W | 3000VA / 2100W |
Ausgangsleistungsfaktor | 0.70 | 0.70 | 0.70 |
Eingang | |||
Eingangsspannungsbereich | 162-290 VAC | 162-290 VAC | 162-290 VAC |
Frequenz (Synchronisationsbereich) | 50Hz or 60Hz | 50Hz or 60Hz | 50Hz or 60Hz |
Output | |||
Ausgangsnennspannung | 208/220/230/240 VAC | 208/220/230/240 VAC | 208/220/230/240 VAC |
Reine Sinuswelle | Ja | Ja | Ja |
THDv | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) | ≤2% @ 100% linear load, ≤5% @ 100% non-linear load (before low battery alarm) |
Spannungsregelung (Bat. Mod.) | ±1.5% (before battery alarm) | ±1.5% (before battery alarm) | ±1.5% (before battery alarm) |
Frequency (Battery Mode) | ±1Hz | ±1Hz | ±1Hz |
Technische Details | |||
Load Crest Ratio | 3:1 | 3:1 | 3:1 |
Transfer Time [AC to Battery] | 2-6ms (typical, 10ms max) | 2-6ms (typical, 10ms max) | 2-6ms (typical, 10ms max) |
Ladegerät | 1.4A | 1.4A | 1.4A |
Protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection | Overload, discharge, and overcharge protection |
Fan Logic | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged | Controlled by adjusting fan speed in 5% steps. Fan off under 40degC; line mode; batteries charged |
LCD Indicators | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, and Low Battery |
Effizienz | |||
Netzmodus Vollast | 96.0% | 96.0% | 96.0% |
BATTERY mode full Load | 90.0% | 90.0% | 90.0% |
Energy Star compliance | t | t | t |
Batterien und Überbrückungszeit | |||
Akkus | 4x 12V/9Ah | 4x 12V/9Ah | 4x 12V/9Ah |
DC Spannung | 4 x 12V | 4 x 12V | 4 x 12V |
Recharge Time | 4h to 90% | 4h to 90% | 4h to 90% |
Full Load Backup Time | 1.5min | 1.5min | 1.5min |
Half Load Backup Time | 4min | 4min | 4min |
Anschlüsse und Kommunikation | |||
IEC C13 Outlet | 8 | 8 | 8 |
Programmable Outlets | 4 | 4 | 4 |
Eingang | C20 | C20 | C20 |
Software | ViewPower | ViewPower | ViewPower |
USB port | Ja | Ja | Ja |
HID-Unterstützung | Ja | Ja | Ja |
RS-232 Port | Ja | Ja | Ja |
Extension Slot | Ja | Ja | Ja |
EPO Port | Ja | Ja | Ja |
Umgebung | |||
Geräuschpegel | < 45dB | < 45dB | < 45dB |
Temperatur | 0°C – 40°C | 0°C – 40°C | 0°C – 40°C |
Luftfeuchtigkeit | 20% - 90% RH (non-condensing) | 20% - 90% RH (non-condensing) | 20% - 90% RH (non-condensing) |
IEC 62040-3 Klassifizierung | VI-SS-211 | VI-SS-211 | VI-SS-211 |
Logistik | |||
Packungsinhalt | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable | UPS, Manual, USB Cable, Input Power Cable, 2x IEC Cable |
Sprache Bedienungsanleitung | EN | EN | EN |
Breite | 145mm | 145mm | 145mm |
Höhe | 220mm | 220mm | 220mm |
Tiefe | 455mm | 455mm | 455mm |
Gewicht | 20.3kg | 20.3kg | 20.3kg |
Verpackung - Breite | 235mm | 235mm | 235mm |
Verpackung - Höhe | 325mm | 325mm | 325mm |
Verpackung - Tiefe | 540mm | 540mm | 540mm |
Verpackung - Gewicht | 22.3kg | 22.3kg | 22.3kg |