Produktvergleich
UPS 1 [x] | UPS 2 [x] | UPS 3 [x] | |
Allgemeine Merkmale | |||
Model | |||
Main Picture | |||
Pictures | |||
Item Number | 10120130 | 10120130 | 10120130 |
EAN | 4260074974713 | 4260074974713 | 4260074974713 |
Features |
|
|
|
Typ | Online | Online | Online |
Kapazität | 6000VA / 5400W | 6000VA / 5400W | 6000VA / 5400W |
Ausgangsleistungsfaktor | 0.90 | 0.90 | 0.90 |
Eingang | |||
Eingangsspannungsbereich | 120-276 VAC Depends on Load Level | 120-276 VAC Depends on Load Level | 120-276 VAC Depends on Load Level |
Max THDi | ≤5% | ≤5% | ≤5% |
Eingangsleistungsfaktor | ≥ 0.99 at full load | ≥ 0.99 at full load | ≥ 0.99 at full load |
Frequenzbereich | 45Hz - 55Hz or 54Hz - 66Hz | 45Hz - 55Hz or 54Hz - 66Hz | 45Hz - 55Hz or 54Hz - 66Hz |
Frequenz (Synchronisationsbereich) | 45Hz - 55Hz or 54Hz - 66Hz | 45Hz - 55Hz or 54Hz - 66Hz | 45Hz - 55Hz or 54Hz - 66Hz |
Output | |||
Ausgangsnennspannung | 208/220/230/240 VAC | 208/220/230/240 VAC | 208/220/230/240 VAC |
Reine Sinuswelle | Ja | Ja | Ja |
THDv | ≤2% Full Linear Load; ≤5% Non-Linear Load | ≤2% Full Linear Load; ≤5% Non-Linear Load | ≤2% Full Linear Load; ≤5% Non-Linear Load |
Spannungsregelung (Bat. Mod.) | ±1% | ±1% | ±1% |
Frequency (Battery Mode) | ±0,1Hz | ±0,1Hz | ±0,1Hz |
Technische Details | |||
Parallelbetrieb | Up to of the same size | Up to of the same size | Up to of the same size |
Load Crest Ratio | 3:1 | 3:1 | 3:1 |
CVCF | Yes, but requires de-rating to 60% | Yes, but requires de-rating to 60% | Yes, but requires de-rating to 60% |
Transfer Time [AC to Battery] | 0ms | 0ms | 0ms |
Transfer Time [Inverter to Bypass] | 0ms | 0ms | 0ms |
Transfer Time [Inverter to ECO] | 1ms | 1ms | 1ms |
Transfer Time [ECO to Inverter] | 10ms | 10ms | 10ms |
Bypass | Before UPS Power-on: Default “No” Change to “Yes” via display panel Overload und UPS Failure: Automatically transfer to bypass By Setting: Voltage Rang: 120-276V ± 3% | Before UPS Power-on: Default “No” Change to “Yes” via display panel Overload und UPS Failure: Automatically transfer to bypass By Setting: Voltage Rang: 120-276V ± 3% | Before UPS Power-on: Default “No” Change to “Yes” via display panel Overload und UPS Failure: Automatically transfer to bypass By Setting: Voltage Rang: 120-276V ± 3% |
Generator-Unterstützung | Ja | Ja | Ja |
Überlastfähigkeit | 2min @102%-130%; 30s @130%-150%; 100ms @ >150% | 2min @102%-130%; 30s @130%-150%; 100ms @ >150% | 2min @102%-130%; 30s @130%-150%; 100ms @ >150% |
Externer Akkuanschluss | Ja | Ja | Ja |
Ladegerät | 1A | 1A | 1A |
Fan Logic | Always on, automatic speed control | Always on, automatic speed control | Always on, automatic speed control |
LCD Indicators | UPS status, Load level, Battery level, Input/Output voltage, AC mode, battery mode, Bypass mode, fault conditions; LCD Display colour : Blue, red, red flashing (depends on UPS status), direction swappable (rack/tower) | UPS status, Load level, Battery level, Input/Output voltage, AC mode, battery mode, Bypass mode, fault conditions; LCD Display colour : Blue, red, red flashing (depends on UPS status), direction swappable (rack/tower) | UPS status, Load level, Battery level, Input/Output voltage, AC mode, battery mode, Bypass mode, fault conditions; LCD Display colour : Blue, red, red flashing (depends on UPS status), direction swappable (rack/tower) |
Effizienz | |||
Netzmodus Vollast | 93.3% | 93.3% | 93.3% |
BATTERY mode full Load | 89.0% | 89.0% | 89.0% |
Energy Star compliance | Ja | Ja | Ja |
Batterien und Überbrückungszeit | |||
Akkus | 15x 12V/5Ah | 15x 12V/5Ah | 15x 12V/5Ah |
DC Spannung | 15 x 12V | 15 x 12V | 15 x 12V |
Recharge Time | 3h to 90% | 3h to 90% | 3h to 90% |
Full Load Backup Time | 3.4min | 3.4min | 3.4min |
Half Load Backup Time | 9.8min | 9.8min | 9.8min |
Anschlüsse und Kommunikation | |||
IEC C13 Outlet | 4 | 4 | 4 |
IEC C19 Outlet | 2 | 2 | 2 |
Klemmanschluss | Ja | Ja | Ja |
Eingang | Terminal | Terminal | Terminal |
Software | WinPower | WinPower | WinPower |
USB port | Ja | Ja | Ja |
HID-Unterstützung | Ja | Ja | Ja |
RS-232 Port | Ja | Ja | Ja |
Extension Slot | Ja | Ja | Ja |
Dry Contacts | Ja | Ja | Ja |
EPO Port | Ja | Ja | Ja |
Umgebung | |||
Geräuschpegel | < 45dB | < 45dB | < 45dB |
Temperatur | 0°C – 40°C | 0°C – 40°C | 0°C – 40°C |
Luftfeuchtigkeit | 0% - 95% RH (non-condensing) | 0% - 95% RH (non-condensing) | 0% - 95% RH (non-condensing) |
IEC 62040-3 Klassifizierung | VFI-SS-111 | VFI-SS-111 | VFI-SS-111 |
Logistik | |||
Packungsinhalt | UPS, Manual, USB Cable, 2x IEC Cable, Tower Holder, Rack Ears, EPO Plug, Parallel Communication Cable | UPS, Manual, USB Cable, 2x IEC Cable, Tower Holder, Rack Ears, EPO Plug, Parallel Communication Cable | UPS, Manual, USB Cable, 2x IEC Cable, Tower Holder, Rack Ears, EPO Plug, Parallel Communication Cable |
Sprache Bedienungsanleitung | EN/PL/DE | EN/PL/DE | EN/PL/DE |
Breite | 438mm | 438mm | 438mm |
Höhe | 129mm | 129mm | 129mm |
Tiefe | 698mm | 698mm | 698mm |
Gewicht | 46kg | 46kg | 46kg |
Verpackung - Breite | 955mm | 955mm | 955mm |
Verpackung - Höhe | 305mm | 305mm | 305mm |
Verpackung - Tiefe | 578mm | 578mm | 578mm |
Verpackung - Gewicht | 50kg | 50kg | 50kg |